40 automatisms inside, to drive filter pump, frost free, user slots or smart timer, all regulations chlorine, bromine, ph-, ph+, oxy, salt chlorinator, UV light, 1 to 8 speeds pumps automatism in any season, backwash protocol, water level protocol wih 1,2,3 or 4 sensors. 2 kinds of analyzers (analogic or modbus) up to 5 sensors, extra satellites for more relays, more dry contacts... really smart!
Yes, you just have to connect the main power line to a 30 mA protection. This boxe allow 3 phasis entry, with 3 x 30A fuses. 6 relays NO 30A, 3 relays NO/NC 20A and 6 relays NO 5A. The wiring is 220V for 9 relays, 1 relay 12 VAC 50VA, 3 unconnected
Yes of course you can change tension from 0 to 220 V - 12 VAC and 12 VDC inside on any relay to drive your specific equipment.
Relays 13 to 15 are built to drive a 3 speeds pumps with COM/NO/NC entries to connect common, stop and 3 wires speed. Then just add 3 speed pump on the app on device n° 13.
The best way is to connect 2 wires between the heat pump flow detector wire and a relay, then add a new heater device on the app on the relay number you are connected. Put your heater at the maximum heating value, then manage the setpoint you want at a time with your app. For electrical heater, just connect resistors to 30A relay.
Globally we offer 3 years warranty on electronics. Sensors and consummables are exclued
3 possiblities, you reaches your wifi spot or can extand you wifi with an extender, Or ask for a radio ethernet emitter/transmitter (250 m range), or ask for a 4G dongle connection if any GSM network is reachable.
Yes, depending on the satellites or option you have, the controller can transform your salt chlorinator in smart devices if you have an analyzer connected and make treatment regarding setpoint and sensor records, or just as filtration pump slave as it is today.
Modbus RTU is a common protocol in automation industry. Open source, all 9600 bps - 8 N 0 format equipment is compatible with the modbus master. We developp Satellites with this protocol to save relay connexion and increase the number of installable equipment