40 automatisms inside, to drive filter pump, frost free, user slots or smart timer, all regulations chlorine, bromine, ph-, ph+, oxy, salt chlorinator, UV light, 1 to 8 speeds pumps automatism in any season, backwash protocol, water level protocol wih 1,2,3 or 4 sensors. 2 kinds of analyzers (analogic or modbus) up to 5 sensors, extra satellites for more relays, more dry contacts... really smart!
Yes, you just have to connect the main power line to a 30 mA protection. This boxe allow 3 phasis entries, with 3 x 30A fuses (load shedding function). 6 relays NO 30A, 3 relays NO/NC 20A and 6 relays NO 5A. The wiring is by default in mono 220V for 9 relays, 1 relay 12 VAC 50VA and 3 unwired
Yes of course you can change tension from 0 to 220 V (12 VAC and 12 VDC inside) on any relay to drive your specific equipment.
Relays 13 to 14 are built to drive a 2 speeds pumps with COM/NO entries to connect 2 phasis. Then just add BI speed pump on the app on device n° 13.
The best way is to connect 2 wires between the heat pump flow detector wire and a relay, then add a new heater device on the app on the relay number you are connected. Put your heater at the maximum heating value, then manage the setpoint you want at a time with your app. For electrical heater, just connect resistors to 30A relay.
Globally we offer 3 years warranty on electronics. Sensors and consummables are exclued
3 possiblities, you can reaches your wifi spot or extand you wifi network with an extender, Or ask for a radio ethernet emitter/transmitter (250 m range) option, or ask for a 4G dongle connection on GSM network if a network exists.
Yes, depending on the satellites or option you have, the controller can transform your salt chlorinator into smart device. If you have an analyzer connected, then treatment is maintained regarding setpoint and sensor records, or just as filtration pump slave as it could be today.
Modbus RTU is a common protocol in automation industry. Open source, all 9600 bps - 8 N 0 format equipment is compatible with the modbus master. We developp Satellites with this protocol to save relay connexion and increase the number of installable equipment.